1. FAB

Step #08 - Connecting the Two Pipes Sections

List of Components

ItemSpecQty 
  Hose section5m2
 Hose end capSteel2
 Clamping RingØ1001
 Quick lock collarØ1002
 Grounding cable/2
 Wire connector2 ways1

Tools needed

Allen Key 6mm

Instructions

  1. At 20cm from the end of the flexible hose, with a box cutter, remove the plastic to expose the hose's copper wire.
    1. Repeat this step for the second hose section.
      1. Connect the grounding wires on the exposed metal on both sections.
        1. Insert the steel end caps in both hose section's ends.
          1. Tighten the clamping ring on both hose sections.
            1. Bend the wires to run parallel (see picture).
              1. Place the quick-lock collar on one hose's end. Pass one of the copper wires through (see picture)
                1. Insert the second hose in the quick-lock collar. Make sure the rubber is correctly placed around it.
                  1. Close the quick-lock collar latch.
                    1. Connect the wires in the wire connector.