8. Limit Sensors & Emergency Stop

Step #03 - Installing the Y1-, Y1+ and Y2- Sensors

List of Components

ItemSpecQty (S/M/L)
 Inductive sensorM123

Tools needed

Spanner 17mm (2x)

Instructions

  1. Place 2 inductive sensors on the Y1-axis (left side, facing the machine), one at each end, and use spanners to tighten them.
    1. Place 1 inductive sensor at the front of the Y2-axis (right side, facing the machine) and use spanners to tighten it.

      Animation

      Use the custom gauge to make sure to the sensors protrude from the steel parts at the correct length.