8. Limit Sensors & Emergency Stop

Step #01 - Installing the Z+ Sensor

List of Components

ItemSpecQty (S/M/L)
 Inductive sensorM121

Tools needed

Spanner 17mm (2x)

Instructions

  1. Place 1 inductive sensor on the Z-axis motor plate and use spanners to tighten it.

    Animation

    Use the custom gauge to make sure to the sensor protrudes from the steel part at the correct length.