Step #04 - Installing the Z+ Sensor
List of Components
Item
Spec
Qty
Inductive sensor
M12
1
Tools needed
Spanner 17mm (2x)
Instructions
Place
1 inductive sensor
on the
Z-axis motor plate
and use spanners to tighten it.
Use the
custom gauge
to make sure the sensor protrudes from the steel part at the correct length.